|
Events
|
Description
|
Comments
|
Intrafrequency
reporting
events for the
FDD mode
|
1a
|
A Primary CPICH enters the reporting range
|
Addition a cell into active set.
|
1b
|
A primary CPICH leaves the reporting range
|
Removal a cell from active set.
|
|
1c
|
A non-active primary CPICH becomes better
than an active primary CPICH
|
Replacement of a cell within the active
set.
|
|
1d
|
Change of best cell in the active set
|
Change the best cell.
|
|
1e
|
A Primary CPICH becomes better than an absolute threshold
|
|
|
1f
|
A Primary CPICH becomes worse than an
absolute threshold
|
|
|
1j
|
A non-active E-DCH but active DCH primary
CPICH becomes better than an active E-DCH primary CPICH
|
|
|
Intrafrequency
reporting
events for the
TDD mode
|
1g
|
Change of best cell (TDD)
|
Used in TDD Mode.
|
1h
|
Timeslot ISCP below a certain threshold
(TDD)
|
Used in TDD Mode.
|
|
1i
|
Timeslot ISCP above a certain threshold
(TDD)
|
Used in TDD Mode.
|
|
Interfrequency
reporting
events
|
2a
|
Change of best
frequency
|
|
2b
|
The estimated quality of the currently
used frequency is below a certain threshold and the estimated quality of a
non-used frequency is above a certain threshold.
|
Inter-frequency handover.
|
|
2c
|
The estimated quality of a non-used
frequency is above a certain threshold
|
|
|
2d
|
The estimated quality of the currently
used frequency is below a certain threshold
|
Enter compressed mode, start measuring
neighbor cells on other frequencies (inter-frequency or inter-RAT) triggered
by low DL signal.
|
|
2e
|
The estimated quality of a non-used
frequency is below a certain threshold
|
|
|
2f
|
The estimated quality of the currently
used frequency is above a certain threshold
|
Leave compressed mode.
|
|
Intersystem
reporting
events
|
3a
|
The estimated quality of the currently
used UTRAN frequency is below a certain threshold and the estimated quality
of the other system is above a certain threshold.
|
Inter-RAT handover.
|
3b
|
The estimated quality of other system is
below a certain threshold
|
|
|
3c
|
The estimated quality of other system is
above a certain threshold
|
|
|
3d
|
Change of best cell in other system
|
|
|
Traffic-volume
reporting events
|
4a
|
Transport Channel Traffic Volume becomes
larger than an absolute threshold
|
|
4b
|
Transport Channel Traffic Volume becomes
smaller than an absolute threshold
|
|
|
Quality
reporting events
|
5a
|
A predefined number of bad CRCs is
exceeded
|
|
UE internal
measurement
reporting events
|
6a
|
The UE Tx power becomes larger than an
absolute threshold
|
Enter compressed mode, triggered by high
UE power level.
|
6b
|
The UE Tx power becomes less than an
absolute threshold
|
Leave compressed mode, triggered by
resolution of 6a.
|
|
6c
|
The UE Tx power reaches its minimum value
|
|
|
6d
|
The UE Tx power reaches its maximum value
|
|
|
6e
|
The UE RSSI reaches the UE's dynamic
receiver range
|
|
|
|
6f
|
The UE Rx-Tx time difference for a RL
included in the active set becomes larger than an absolute threshold
|
FDD
|
6f
|
The time difference indicated by TADV
becomes larger than an absolute threshold
|
1.28 Mcps TDD
|
|
6g
|
The UE Rx-Tx time difference for a RL
included in the active set becomes less than an absolute threshold
|
FDD
|
|
UE positioning
reporting events
|
7a
|
The UE position changes more than an
absolute threshold
|
|
7b
|
SFN-SFN measurement changes more than an
absolute threshold
|
|
|
7c
|
GPS time and SFN time have drifted apart
more than an absolute threshold
|
|
Next
« Prev Post
« Prev Post
Previous
Next Post »
Next Post »
Subscribe to:
Post Comments (Atom)